PN20 Waterproof Proximity Reader
£54.35 ex VAT
PN20 Programmable Standalone Proximity Reader
The PN20 waterproof proximity reader is a robust and reliable access control reader designed for secure outdoor installations. Built to withstand harsh weather conditions, the access control system provides dependable contactless access for commercial, industrial and residential applications, making it an ideal solution for professional installers and security specialists.
Compatible with a wide range of access control systems, the PN20 offers fast and accurate card and fob reading, allowing authorised users to gain entry quickly while maintaining high levels of security. Its slim, modern design complements contemporary buildings, while its weather-resistant construction ensures reliable performance in exposed environments throughout the year.
Whether you’re installing a new access control system or upgrading an existing one, the PN20 delivers dependable operation, simple installation and long-term durability.
Key Features:
- Weatherproof design for indoor and outdoor installations
- Fast and reliable RFID card and fob reading
- Modern slimline appearance
- Suitable for commercial and industrial applications
- Durable construction for long-term reliability
- Compatible with a wide range of access control systems
- Easy to install
- Ideal for new installations and system upgrades
Frequently Asked Questions
- Is the PN20 suitable for outdoor use? Yes. The PN20 is designed for external installations and features a weatherproof housing suitable for year round outdoor use.
- What can the PN20 read? The reader is designed to work with compatible proximity cards and key fobs.
- Can it be used with magnetic locks? Yes. When connected to a compatible access control controller, the PN20 can be used with magnetic locks, electric strikes and other electronic locking devices.
- Is it suitable for commercial buildings? Â The PN20 is widely suited to offices, schools, hospitals, warehouses, apartment buildings and industrial facilities.
- Can the PN20 be installed on gate posts? Yes. Its slim design makes it suitable for mounting on walls, narrow door frames and gate posts where installation space is limited.
- Is it suitable for new and existing systems? Yes. The PN20 can be used as part of both new access control installations and upgrades to existing systems, subject to system compatibility.
- Working voltage: 9/24Vdc
- Strong metal vandal resistant case
- Easy to install and program with admin cards or IR programmer
- Standalone
- Adjustable relay time (1-300Â seconds, or latching mode)
- 2000 users
- Frequency: 125KHz
- Reading range 3-8cm
- Environment temperature: -40°C to 60°C
-
Pulse mode, toggle mode
-
Built in LDR for anti tamper
-
Card block enrolment
- Dimensions: 103 x 48 x 19 mm
- IP66 rated
- 0.5 metre pre-wired cable
- 2 Year warranty
- Office buildings
- Schools and colleges
- Hospitals and healthcare facilities
- Warehouses and distribution centres
- Factories and industrial units
- Apartment buildings
- Commercial entrances
- Staff entrances
- Secure storage areas
- Gated developments
Forgotten the master code
- Perform a factory reset. Master code will be reset to default. (123456)
- How to: Power off, press and hold the exit button whilst powering up the unit. There will be 2 beeps, release the exit button, the LED turns yellow. Then read any two EM 125KHz cards, the LED will turn red. The first card read is the master add card, the second card read is the master delete card. User data is unaffected.
Lost the master cards
- Any two EM cards can be programmed as master cards. Perform a factory reset: Power off, press and hold the exit button whilst powering up the unit. There will be 2 beeps, release the exit button, the LED turns yellow. Then read any two EM 125KHz cards, the LED will turn red. The first card read is the master add card, the second card read is the master delete card. User data is unaffected.
Reader isn’t beeping when fob or card is presented
- Check your cards or fobs are the correct type & frequency for the reader. They must be 125KHz EM.
3 beeps when trying to program something into a User ID
- User ID is already taken, please try a different one.
How do I delete a specific fob or card?
- When the device was installed, an issue record should have been kept. This may be on the last page of the supplied manual or kept digitally. Refer to the issue record and see page 5 of the manual.
- If no issue record was kept, you may need to delete all users and re-add them.
Unexpected beeping or flashing or not reading cards properly
- This can often be caused by a faulty power supply or not enough current. Fit a new transformer.
- Double check all cabling and connections. Take off the wall and connect directly to the power supply to rule out any cabling issues or short circuits.