EL00PM-RAD Post Mount Magnetic Vehicle Detector
From £348.60 ex VAT
Above ground vehicle detector by AESÂ
The Above Ground Wireless Magnetic Vehicle Detector provides a reliable and easy-to-install vehicle detection solution for automatic gates, barriers, and access control systems. Ideal for driveways and entrances where traditional inductive ground loops are impractical, this innovative system eliminates the need for cutting into road surfaces or running detection cables back to the gate controller.
Designed for side-mounted installation, the detector is fitted to a post approximately 600mm above ground level, with the sensor facing the desired detection zone. Using advanced military-grade magnetometer technology combined with radar confirmation, the system accurately detects the presence and movement of vehicles at distances of up to 3 metres.
When a vehicle enters the detection area, the sensor wirelessly transmits a signal to the receiver located within the gate control panel, triggering the gate or barrier to open automatically. This makes it an ideal solution for residential driveways, commercial entrances, private roads, and automated vehicle access systems.
Key Features:
- Wireless Vehicle Detection – No road cutting, trenching, or signal cables required.
- Above Ground Installation – Ideal for locations unsuitable for traditional inductive loops.
- Military-Grade Magnetometer Sensor – Highly accurate vehicle detection technology.
- Radar Confirmation Technology – Enhances reliability by confirming vehicle movement and presence.
- Detection Range Up to 3 Metres – Suitable for a wide range of driveway and vehicle access applications.
- Presence & Exit Detection Modes – Can operate in presence mode and exit mode when configured with the appropriate diagnostic tool.
- Long Battery Life – Powered by 2 x 1.5V 3000mAh AA lithium batteries with up to 2 years of operational life.
- High Security Communication – Protected by 128-bit encrypted wireless transmission.
- Compact Design – Measures just 176mm (H) x 70mm (W) x 30mm (D).
- IP68 Rated – Fully weatherproof and designed for reliable outdoor operation in harsh environments.
Unlike traditional inductive loop detectors, the Above Ground Wireless Magnetic Vehicle Detector offers a fast, cost-effective installation with minimal disruption, making it an excellent choice for both new installations and retrofit projects.
- Power:Â 2 * 1.5 V 3000ma AA Lithium Batteries
- Dimensions:Â 176mm*70mm*30mm
- Weight: 200g E-LOOP Only
- Environment:Â To be post-mounted 600mm from the ground
IP68 ingress protection - Operating Temp: -40° to 80° C
- Standby Power: 14µA
- Activation Power:Â 35mA
- Automatic gates
- Electric gate systems
- Residential driveways
- Commercial entrances
- Industrial sites
- Vehicle barriers
- Private roads
- Access control systems
- Locations where ground loops cannot be installed
â–ª e-Loop will not code to the transceiver
Answer:
- Ensure loop is held directly beside transceiver for pairing process, initiate code process on transceiver, this should automatically detect loop and successfully pair if close enough. For commercial or inground loops: these can be paired in close proximity or in location by using pairing method 2.
- (See video linked below.)
https://youtu.be/3FcmmoQKl2Q?t=23
â–ª What is the maximum distance between the e-Loop and transceiver?
Answer:
The loop can be placed up to 50M away from the transceiver using supplied antenna, ensure a clear line of sight between loop & transceiver. Please note: housing the transceiver in a metal enclosure or close to high voltage power lines could reduce the transmission range. If you are having issues, please try house the transceiver in its own separate enclosure or try an external antenna.
â–ª How do I reset an e-Trans50?
Answer:
- Press and hold the code button for approx. 11 seconds until you see all 3 LED’s on transceiver flash up. This will clear the memory of the transceiver, you can then go ahead and start the pairing/coding process with your loop/s.
- (See video linked below.)
https://youtu.be/wPtsT1zbzAU
â–ª I have paired the loop, but it is not triggering the gate/barrier
Solution:
Test by placing metal object or driving vehicle over loop, on the transceiver check if Red/RX LED comes on while doing so, this will indicate the loop is triggering and signal sent to transceiver firstly. If gate is not triggering, double check wiring from gate motor, you can also test & prove relay is changing state by using a multi-meter. If still having issues, please call technical support to discuss further. +44 28 8639 0693
â–ª Can I pair more than one e-loop to a transceiver?
Answer:
Yes, up to 4 can be paired.
| Weight | 2 kg |
|---|---|
| Dimensions | 176 × 70 × 30 mm |
| Options | EL00PM-RAD E-LOOP Only, EL00PM-RAD-K E-LOOP With ETRANS-50, EL00PM-RAD-KLT E-LOOP With ETRANS-200, EL00PM-RAD-KT E-LOOP With ETRANS-100, EL00W-RAD Wired Loop with 20m Cable |