DMR-IND Deadman Three Phase Control Panel
£81.88 ex VAT
DMR-IND Industrial Door Control Panel (Single & Three Phase)
The DMR-IND is a robust and reliable control panel designed for industrial and commercial door applications. Suitable for both single phase and three phase motors, it provides precise and compliant control for roller shutter and sectional doors.
The panel allows for either automatic or deadman opening (selectable via dipswitch), with closing controlled exclusively by deadman operation for enhanced safety. Deadman control ensures the door only moves while the button is actively pressed, stopping immediately when released.
To support safe operation and regulatory compliance, the transmitter range can be adjusted via an onboard potentiometer. This allows installers to limit operation to within direct line of sight of the door, in line with EN 60335-1:2012 requirements.
Key Features:
- Suitable for single-phase and three-phase motors
- Designed for industrial and commercial roller shutter and sectional doors
- Selectable automatic or deadman opening (via dipswitch)
- Deadman closing only for improved operational safety
- Compatible with deadman transmitters
- Adjustable transmitter range via potentiometer
- Limit switch inputs for accurate positioning
- Stop button input for immediate control
- Key switch and rocker switch input compatibility
- Supports motors up to 1.2kW with mechanical limit switches
- Industrial control panel for roller shutters and sectional doors.
- Deadman activation range from the transmitter is adjustable using a potentiometer.
- Operable with a dead man function or mixed semi-automatic (automatic open, close dead man) by using optional selector.
- It has no safety inputs.
- It works with dead man transmitters.
- 27 code memory, expandable to 500 with MEM500.
- Mechanical limit switch inputs.
- Control buttons on the cover.
- Additional control button inputs.
- Max motor power (3 phase): 400Vac (1.2kW)
- Max motor power (1 phase): 230Vac (1.2kW)
- 5 Year Warranty!
Single & 3 phase motors up to 1.2KW on roller and sectional doors, where the motor has mechanical limits and the customer is happy with deadman closing only.
▪ Door won’t open and/or close
Solution:
- If fitted, check the emergency stop button hasn’t been pressed and the cable is undamaged. If not fitted, check the terminals are linked.
- Link out all 3 limit switch terminals. If this works, check the limit switch wiring and adjust the limits at the motor if necessary.
- If the relays are clicking, check the motor wiring is correct.
- Check there is power to the control panel and check the fuse.
â–ª Panel beeps when pressing a remote
Answer:
- Transmitter is out of range. Move closer or adjust the range with the blue potentiometer.
▪ Remote control won’t program
Answer:
- Check that both the three phase control panel and remote control were purchased from Quantek.
- Check you have a deadman transmitter.
â–ª The panel is opening in deadman but I want to open in auto
Answer:
- Turn the options dipswitch off (down position).
â–ª The panel is closing in deadman but I want it to close in auto
Answer:
- This is not possible, it is a deadman closing panel only.
- Upgrade to the i20 if you want automatic closing.
| Weight | 0.95 kg |
|---|---|
| Dimensions | 152 × 180 × 88 mm |